2120XP钙硬度表|美国奥立龙ORION
精确测量纯水中钙硬
领 域:电力、造纸、石化、饮用水
应 用:沸石软化器出水监测;软化水监测;中水处理出水
特 点:
l 离子电极直接测量技术
l 25ppb 检测限
l 两点已添加法自动校正(DKA)
l 宽量程,报警功能
l 操作简单,维护方便,运行费用低
低配置信息:
| 订货号 |
名称 |
| 2120XP |
2120XP钙硬度表 (不含主表外保护箱) |
| 2120XPEN |
2120XP钙硬度表 (含主表外保护箱) |
试剂及附件:
| 订货号 |
试剂及附件 |
描述 |
| 182011 |
Formic Acid Reagent |
60 day supply- includes (1) x 1 L bottle formic acid reagent and (1) x 2 ft long diffusion tubing with O-rings (181060) |
| 182011F* |
Reagent-less Formic Acid Reagent Bottle |
Includes (1) x 1 L empty bottle for use with formic acid reagent (182011) and (1) x 2 ft long diffusion tubing with O-rings (181060) |
| 182011F6* |
Reagent-less Formic Acid Reagent Bottle |
Includes (6) x 1 L empty bottles for use with formic acid reagent (182011) and (6) x 2 ft long diffusion tubing with O-rings (181060) |
| 181060 |
Fluoride Diffusion Tubing |
(1) x 2 ft long diffusion tubing and O-rings |
| 212050XP |
Calcium Hardness Consumables Kit |
Includes (6) x 1 L bottles formic acid reagent and (6) x 2 ft long diffusion tubing with O-rings (182011), calcium standard solution kit (182040), calcium sensing electrode (100049), reference electrode (100056), (1) x 2 oz bottle reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170) |
| 212050XPF* |
Reagent-less Calcium Hardness Consumables Kit |
Includes (6) x 1 L empty bottles for use with formic acid reagent (182011), (6) x 2 ft long diffusion tubing with O-rings (181060), calcium standard solution kit (182040), calcium sensing electrode (100049), reference electrode (100056), (1) x 2 oz bottles reference electrode filling solution (181073), O-ring kit (2100OK), check valve (2100VC), pipette tips (204846-001), restriction tube assembly (2100RT) and inlet filter with gaskets (181170) |
| 181160 |
High Acid Diffusion Tubing |
(3) x 5’8” long thin-walled diffusion tubing and O-rings for high alkalinity samples, 6 month supply | 电极及附件:
| 订货号 |
电极及附件 |
描述 |
| 181073 |
Reference electrode filling solution |
(5) x 2 oz bottles for use with reference electrode (100056) |
| 2100TP |
2100 Series Automatic Temperature Probe |
With ground (30 kΩ), for use with 2120XP |
| 2001XT |
2100 Series Automatic Temperature Probe |
With 10 meter extension cable and ground (30 kΩ), for use with 2120XP |
| 100049 |
Calcium Sensing Electrode |
For use with 2120XP |
| 100056 |
Calcium Reference Electrode |
for use with 2120XP, includes reference electrode filling solution (181073) |
| 182040 |
Calcium Standard Solution Kit |
Includes (2) x 2 oz bottles of calcium standard 1 (191 ppm) and (2) x 2 oz bottles of calcium standard 2 (1920 ppm) |
| 2120XPEK |
Calcium Electrode Kit |
Includes calcium sensing electrode (100049), reference electrode (100056), and reference electrode filling solution (181073) |
| 2120XPCAL |
Calibration Kit |
Includes carrying case, 0.5 mL pipette (204847-001), box of pipette tips (204846-001), wash bottle, (1) x 2 oz bottle calcium standard 1 (191 ppm), (1) x 2 oz bottle calcium standard 2 (1920 ppm) and (1) inlet filter |
| 21003M |
Extension Cables |
(2) x 3 meter cables, for 100029 and 100056 electrodes | 技术参数:
| Response Time : |
Reach 95% of final reading within 2 minutes of injecting a standard solution |
| Units displayed : |
ppb, ppm (auto ranging) |
| Temperature : |
5 to 35 ˚C |
| Total Alkalinity : |
less than 250 ppm CaCO3 |
| Inlet pressure : |
8 to 100 psig |
| Flow rate : |
40 mL/min nominal set by pressure regulator |
| Sample inlet : |
1/4” NPTF tube fitting |
| Sample drain : |
3/4” NPT male |
| Grab sampler supported : |
YES |
| Analog output : |
Galvanically isolated |
| # of analog outputs : |
2, one dedicated to calcium hardness, one to temperature; shared ground |
| Output selections : |
0 - 20 mA or 4 - 20 mA |
| Programmable range : |
YES |
| Log & linear output options : |
YES, user selectable |
| Alarm outputs : |
3 |
| Number of relay outputs : |
3 |
| Maximum relay load : |
250 VAC, 5 A, 30 VDC |
| Min/Max Value Alarm : |
YES |
| Error alarm : |
YES |
| Calibration/offline alarm : |
YES |
| Programmable min & max values : |
YES |
| Electronics : |
144 x 144 x 187 mm |
| Entire system dimensions : |
65 x 45 x 27 cm (26” x 17” x 11”) Fits on 1820AO panel mounting footprint. |
| Input : |
85-132 or 170-264 VAC |
| Self-test & diagnostics : |
YES |
| Password protection : |
YES |
| Programmable alarms : |
High, low, error, calibration/offline |
| Waterproof enclosure : |
IP66 & NEMA 4X |
| Regulatory and Safety : |
CE, CSA, UL, FCC Class A limits |
| Case Material : |
Valox 364 |
|